Today, this kind of radiotherapy that used to treat cancer has been upgraded with more high technology being used in that system. The new system (TrueBeam) that's being used nowadays brought a lot of special characteristics and been modified by using high energy ray to spot the cancer or tumour without destroying the healthy tissues.
TrueBeam is more fast, accurate and efficient compared to the other system. Other than that, TrueBeam usually only took a few minutes to do the diagnoses and treatment to patients than older system or surgery which usually took almost an hour. This system is generated by a machine called Medical Linear Accelerator that integrates imaging and radiation delivery. The Truebeam can be targeted at a tumor from any angles in three-dimensional shape to know its size, shape, and location. It also rotated around the patients to deliver the amount of radiation needed in correct angles with submillimetre accuracy and varying intensity. There are two types technique that has been used in the TrueBeam such as Intensity Modulated Radiotherapy (IMRT) and Image Guided Radiotherapy (IGRT).
CHARACTERISTIC OF TRUEBEAM
Latest Treatment
- IMRT
- IGRT
- Gated RapidArc
- SBRT
- SRS
TrueBeam Paired Imaging.kV
Cone Beam CT – CBCTTrueBeam
MV Imaging.TrueBeam
Fluoroscopy.TrueBeam
- Gated RapidAch Technology - produce a 3D image with 360
of rotation 60% faster compared to the other technology with 25% lesser of usage dose.degrees
- Calypso system, the positioning device.
the movingMonitor at the real time.tumour
- ARIA® oncology information system.
to transfer bigCapable such as the imaging picture filesfiles data
- The gated R
systemapidArc .
third party clinicians monitoring the motion ofEnable .tumour
treatment up to 50% faster compared to the previous version of VDeliver technology.arian
- IGRT and CBCT can be done in 60% less time and 25% less dose compared to other technology.
accuracy.Pinpoint
accuracy checks every ten milliseconds throughout the entire treatment.Performs
FEATURE OF TRUEBEAM
The TrueBeam system boasts multiple layer of safety for patient, the system component and the user. Among the system's safeguard area physical, software, audible and visual mechanism specifically designed to help ensure safe operation of the treatment. These features work together to help improve patient safely, while allowing clinicians to navigate the complexities of cancer care with coincidence.
- Touch Ground
- Capacitive Collision Detection System
- Machine Motion Model
- Zone Rules
- Live View Monitoring System
- Visual and Audio Monitoring System
- Standardized User Interfaces
- Pre-treatment Dry Run Capability
II Infrared Laser CollisionLaserguard
Input Process of TrueBeam
- The data captured after using the TrueBeam Varian treatment are transfer to the Treatment Planning System (TPS) to generate treatment plan
- A physicist check the plan quality and evaluate its deliverability then approve.
- The plan are sent to the Treatment Management System (TMS)
- The plan are then transferred to the linear accelerator(fastest straight pathway of data) for delivery.
- The treatment plan from TPS sent through DICOM to the database (network drive)
- For analysis, the TrueBeam trajectory log files of the treatment plan are recorded and transfer to the database (network drive).
Processing Of Truebeam
- The TrueBeam Varian Medical Systems, a new log file called trajectory log file system.
- By using the new log trajectory log file system the data will provide a definite Quality assurance (QA)-Quality Control (QC) check which can increase the safety of Radiation Therapy (RT).
- The log file will find the patient ID then compare the delivered data against their original planned values of their jaw position, the beam energy, the gantry angle, the collimator angle, couch angle and the number of segments used for the next treatment.
- This TrueBeam log file analysis has an ability to catch any error related to data transfer quality without any additional effort.
- The comparison between The TrueBeam log files from the database with the DICOM treatment plan files exported from treatment planning system (TPS).
Output Process
- The MATLAB (MathWorks, Natick, MA) software use the beam on-off status and MultiLeaf Collimator (MLC) leaf positions from the TrueBeam log files to calculate and reconstruct the equivalent fluence map.
- The MLC positions recorded in the log files are then will be validated by a physicist.
- The QA are checked manually weekly to reduce any possible error.
- Automatic TrueBeam trajectory log file analysis ensure the data delivery quality,it is efficient, accurate, used less human involvement that might cause error during data input process.
- The data are printed into report for the physicist informan.